Arq Bras Oftalmol ; 76(4): 215-7, 2013.
Artigo em Inglês | MEDLINE | ID: mdl-24061830

RESUMO

PURPOSE: Evaluate contact lenses fitting after intracorneal ring implantation for keratoconus, its visual acuity and comfort. METHODS: Retrospective study of patients undergoing contact lenses fitting, after intracorneal ring for keratoconus. The criterion for contact lens fitting was unsatisfactory visual acuity with spectacle correction as referred by the patients. All patients were intolerants to contact lenses prior to intracorneal implantation. Visual acuity analysis was done by conversion of Snellen to logMAR scales. The comfort was evaluated according subjective questioning of good, medium or poor comfort. RESULTS: Nineteen patients were included in the study. Two patients (10.5%) did not achieved good comfort with contact lenses and underwent penetrating keratoplasties. All the others 17 patients showed good or medium comfort. Four rigid gas-permeable contact lenses were fitted, one piggyback approach, 3 toric soft contact lenses, 2 soft lenses specially design for keratoconus and 7 disposable soft lenses. The average visual acuity improved from 0.77 ± 0.37 to 0.19 ± 0.13 logMAR units after contact lenses fitting. CONCLUSION: Contact lens fitting after intracorneal ring is possible, provides good comfort, improves visual acuity, and therefore, may postpone the need for penetrating keratoplasty.


Assuntos
Lentes de Contato , Substância Própria/cirurgia , Ceratocone/cirurgia , Próteses e Implantes , Ajuste de Prótese , Implantação de Prótese/métodos , Adolescente , Adulto , Topografia da Córnea , Feminino , Humanos , Masculino , Estudos Retrospectivos , Resultado do Tratamento , Acuidade Visual , Adulto Jovem
2.
Arq. bras. oftalmol ; 76(4): 215-217, jul.-ago. 2013. tab
Artigo em Inglês | LILACS | ID: lil-686555

RESUMO

PURPOSE: Evaluate contact lenses fitting after intracorneal ring implantation for keratoconus, its visual acuity and comfort. METHODS: Retrospective study of patients undergoing contact lenses fitting, after intracorneal ring for keratoconus. The criterion for contact lens fitting was unsatisfactory visual acuity with spectacle correction as referred by the patients. All patients were intolerants to contact lenses prior to intracorneal implantation. Visual acuity analysis was done by conversion of Snellen to logMAR scales. The comfort was evaluated according subjective questioning of good, medium or poor comfort. RESULTS: Nineteen patients were included in the study. Two patients (10.5%) did not achieved good comfort with contact lenses and underwent penetrating keratoplasties. All the others 17 patients showed good or medium comfort. Four rigid gas-permeable contact lenses were fitted, one piggyback approach, 3 toric soft contact lenses, 2 soft lenses specially design for keratoconus and 7 disposable soft lenses. The average visual acuity improved from 0.77 ± 0.37 to 0.19 ± 0.13 logMAR units after contact lenses fitting. CONCLUSION: Contact lens fitting after intracorneal ring is possible, provides good comfort, improves visual acuity, and therefore, may postpone the need for penetrating keratoplasty.


OBJETIVOS: Avaliar a adaptação de lentes de contato após implante de anel intracorneano para ceratocone perante a acuidade visual e o conforto. Local: Hospital de Olhos do Paraná, Curitiba, Paraná. MÉTODOS: Estudo retrospectivo de pacientes submetidos à adaptação de lentes de contato após implante de anel intracorneano em pacientes com ceratocone. A impossibilidade do uso de lentes de contato foi usada como critério para indicação de implante de anel intracorneano, sendo a adaptação de lentes de contato reservada aos pacientes com acuidade visual menor que o desejado após o implante. A acuidade visual foi considerada segundo a correlação entre a tabela de Snellen e a tabela de logMAR. O conforto foi avaliado segundo o questionamento subjetivo entre lentes confortáveis, conforto moderado e lentes desconfortáveis. RESULTADOS: Foram incluídos 19 pacientes no estudo. Apenas 2 pacientes (10,5%) não alcançaram um conforto adequado com as lentes de contato, sendo encaminhados para transplante de córnea. Nos outros 17 pacientes foram adaptadas: 4 lentes de contato rígidas gás-permeáveis​​, 1 sistema à cavaleiro, 3 lentes de contato gelatinosas tóricas, 2 lentes para ceratocone e 7 lentes gelatinosas descartáveis​​. A acuidade visual média melhorou de 0,7 ± 0,3 para 0,2 ± 0,1 unidades logMAR após a adaptação das lentes de contato. CONCLUSÃO: Adaptação de lentes de contato após anel intracorneano é possível, resulta em bom conforto e melhora da acuidade visual. Todas lentes de contato gelatinosas adaptadas demonstraram-se confortáveis. Esta adaptação pode ser útil aos pacientes que desejem adiar o transplante de córnea.


Assuntos
Adolescente , Adulto , Feminino , Humanos , Masculino , Adulto Jovem , Lentes de Contato , Substância Própria/cirurgia , Ceratocone/cirurgia , Próteses e Implantes , Ajuste de Prótese , Implantação de Prótese/métodos , Topografia da Córnea , Estudos Retrospectivos , Resultado do Tratamento , Acuidade Visual